PDFPrintE-mail
Eurotron-Basic Combustion Analyzer-GBCEurotron-Industrial Combustion and Emission Analyser(HH)-GHH

Eurotron-Compact Combustion Analyser-GCC

( Eurotron )

General

One Instrument with Many Functions

The UniGas 2000+  is the most comprehensive FLUE gas analyser available for:

Boiler tuning and maintenance;

D P boiler filters checks;

Pressure switch tuning;

Water, air, surface temperature measurements;

Draft, gauge and differential

Pressure measurements;

Search for presence and location of gas leaks;

Operator safety with ambient CO and O continuous monitoring.

7 instruments in 1

Combustion Flue

Gas Analyser

Draft & Differential

Pressure Meter

2 Channel

Thermometer

Ambient CO Monitor

Gas Pipe work Leak

Tester

Gas Leak Detector

Ionization Flame Tester

Built-in Impact Printer

Built-in Gas Sniffer

Rechargeable Battery

Easy to Use, Text and

Keyboard in any

Language

Stores up to 250

Samples

Windows Software

Upgradable Using Flash

Memory

Specifications:

Type

palm-top combustion gas analyser with 1 or 2 gas sensors.

Calibration

automatic calibration procedure at instrument switch-On

Self-diagnosis

Sensors efficiency test with display diagnostic messages

Fuel types

Up to 10 selectable from keyboard.

Power supply

High capacity Ni- MH rechargeable battery pack / external battery charger

Charging time

8h at 90% with instrument Off.

Battery life

6 hours (typical) continuous use (without printing and backlight).

Memory

up to 250 full analysis data structured by boilers (Tags)

Printer

Internal impact type 24 columns with 58 mm paper roll (10 meters long).

Printer power supply

from the analyser battery pack.

Print autonomy

up to 40 reports with full battery .

Service and user information

3 programmable lines.

Printed report header

4 programmable lines.

Display

40x58 mm alpha-numeric LCD with backlight device

Flue gas probes

stainless steel shaft with incorporated  temperature sensor.

Serial communication

RS232 serial interface.

Infrared port

compatible with HP82240B cordless printer.

Operating temperature

from -5°C to +45°C

Storage temperature

from -20 to +60°C (3 months maximum at temperatures exceeding the

operational limits).

Dimensions and Weight

115x90x330 mm - 1.1 kg with battery and printer

 

 

Parameter

Sensor

Range

Resolution

Accuracy

O2

Electrochemical

0 - 25%

0.1%

±0.2% vol

CO

Electrochemical

0 - 4000 ppm

1 ppm

±20 ppm <400 ppm

±5% rdg elsewhere

CO H2 compensated

Electrochemical

0 - 8000 ppm

1 ppm

±10 ppm <300 ppm

±4% rdg up to 2000 ppm ±10% rdg elsewhere

CO2

Calculated

0 - 99.9%

0.1%

T air

Pt100

-10 - 100°C

0.1°C

±0.5°C

T gas

TC K

0 - 600°C

0.1°C

±1°C

Pressure/Draft

Piezoresistive

-10hPa to 110hPa

0.01 hPa

±3Pa <300 Pa

±1% rdg. elsewhere

Excess air

Calculated

1.00 - infinity

0.01

Efficiency

Calculated

1 - 99.9%