Opacity & Dust Transmitter

Opacity/ Oxygen Analyser

( Dwyer )

General

The OPAL 100 series transmissometer systems are integrated emissions monitoring systems that provide continuous in-situ measurement of both visible (opacity %) and quantitative (mg/m3) emissions. They are ideal for use in package boiler, incinerator, and combustion process applications where EPA emission limits are applicable and precise combustion control is desired.

OPAL 100 with optional oxygen sensor By incorporating the optional NOVATECH zirconia oxygen sensor, process combustion control can be optimised for improved results. The OPAL 100 provides dual channel output signals and alarm relays for both smoke density and oxygen levels. The total system is integrated into a single analyser control unit which represents significant savings in capital expenditure and installation costs.

Continuous measurement of both stack opacity and dust levels

Optional oxygen sensor as second channel output

Reduce fuel costs and reduce emissions with a single investment

Dual alphanumeric display with analogue and alarm outputs for opacity, dust and oxygen.

Easy access to opacity transceiver and retro for lens cleaning and maintenance.

Double pass, temperature stabilised, and stray light immune optical system.

Long life modulated high power LED light source.

Lens protection purge modules suitable for plant air or independent air blower system.

Unique automatic or manual lens dirt compensation.


Specifications:

OPAL 100 - Control Unit

Enclosure

IP65 weatherproof

Weight

1.8 Kg

Ambient Temperature

-10 to +50 Deg C

Power Supply

120 or 240vac, 50/60Hz, 125vA

Display

Alphanumeric, two line x 16 character x 4mm LCD, backlit

Top Line Display

Opacity %, resolution 0.1%

Lower Line Display

Selectable – Oxygen, Lens Dirt %, alarm & system status, dust (mg/m3)

Operator Indicating LED’s

Power, Alarm active, Setup mode, opacity autozero in progress

Outputs -


Channel 1

Linearised Opacity % - 4-20mA, isolated, scaleable span 10 – 100% opacity

Channel 2

Linearised Oxygen % - 4-20mA, isolated, scaleable span 1 – 100% oxygen

Outputs - Relay

Four (4) programmable SP-NC, 0.5A at 24vdc ( 50vac / 30vdc maximum

Alarms

Optical head set failure, Maintenance mode, Lens dust level high, High opacity High or low oxygen level, Oxygen probe failure

Control Features

OPACITY - Manual or automatic lens dirt compensation, OXYGEN – automatic self calibration



OPAL 100 - Sensors

Enclosure

IP65 weatherproof

Weight (total)

2.5Kg transceiver, 0.8Kg retroreflector Installation Flange

Path Length

300mm to 3600mm

Optical System

Double Pass system using high power LED light source with electronic light modulation

Lens Protection

Optional air purge fittings for either air blower or plant instrument air.

Ambient Temperature

-10 to +50 o C

Process Temperature

Up to 400 o C standard

Ambient Light Immunity

Nil effect from sunlight or artificial light sources.

Peak / Mean Spectral Response

515 to 585 nm, less than 10% of peak response outside 400 to 700 nm

Angle of View

<4.0° from optical axis

Angle of Projection

<4.0° from optical axis

Response Time

< 2 seconds, to 90% of actual value

Zero Calibration / test

Manual or automatic operation, carried out under clean stack conditions.

Span Calibration / test

Manual operation, using optional zero / span filter test module.

Lens Dirt Compensation

Measure and compensate is initiated manually via keypad or remote input signal.

Cable Data