PDFPrintE-mail
Dwyer-Differential Pressure TransmitterDwyer-Differential Pressure Transmitter

Dwyer-Differential Pressure Transmitter

( Dwyer )

General:

Series 616 Transmitters feature exceptional ±0.25% accuracy in several factory calibrated ranges. Choose the one just right for your application. Span and Zero controls included for fine tuning and minor re-calibration in the field.

Positive, negative and differential pressures can be measured within a full span accuracy of ±0.5% with the Dwyer Series 616W Differential Pressure Transmitter. Units are enclosed in a polycarbonate case, rated NEMA 4X (IP66) and operate by sensing the pressure of air and compatible gases then sending a standard 4-20 mA output signal.

Design enables operation in 2-wire current loops. A wide range of models are available factory calibrated to specific ranges. The span and zero controls are for use when checking calibration. They are not intended for re-ranging to a significantly different span.

Specifications: 616 Series

Service

Air and non-combustible, compatible gases.

Accuracy

0.25% F.S.

Stability

+1% F.S./yr.

Temperature Limits

0 to 140°F (-17.8 to 60°C).

Compensated Temp. Limits

20 to 120°F (-6.67 to 48.9°C).

Thermal Effect

±0.055% F.S./°F (0.099% F.S./°C).

Power Requirements

10-35 VDC (2 wire).

Output Signal

4 to 20 mA.

Zero and Span Adjustments

Potentiometers for zero and span.

Loop Resistance

DC; 0-1250 ohms maximum

Current Consumption

DC; 38 mA maximum.

Electrical Connections

Screw-type terminal block

Process Connections

Barbed, dual size to fit 1/8˝ and 3/16˝ (3.12 mm and 4.76 mm) I.D. rubber or vinyl tubing.

Mounting Orientation

Vertical, consult factory for other position orientations.

Weight

1.8 oz (51 g).


Specifications 616W Series

Service

Air and non-combustible, compatible gases.

Accuracy

0.25% F.S.

Stability

+1% F.S./yr.

Temperature Limits

0 to 140°F (-17.8 to 60°C).

Compensated Temp. Limits

20 to 120°F (-6.67 to 48.9°C).

Thermal Effect

±0.055% F.S./°F (0.099% F.S./°C).

Power Requirements

10-35 VDC (2 wire).

Output Signal

4 to 20 mA.

Zero and Span Adjustments

Potentiometers for zero and span.

Loop Resistance

DC; 0-1250 ohms maximum

Current Consumption

DC; 38 mA maximum.

Electrical Connections

Screw-type terminal block

Process Connections

Barbed, dual size to fit 1/8˝ and 3/16˝ (3.12 mm and 4.76 mm) I.D. rubber or vinyl tubing.

Mounting Orientation

Vertical, consult factory for other position orientations.