| General: |
| Each body, at temperatures above the absolute zero (-273°C or 0K), emits energy as electromagnetic radiation. When temperature rises, the intensity of this infrared energy increases. The temperature of the body surface can therefore be determined by measuring the intensity of this energy in a small spectral band: the infrared region. The instruments used to measure this energy and to calculate the related temperature are called infrared thermometers or noncontact thermometers Applications: Temperature measurements of a liquid or gaseous compound have been successfully made with thermoelectric or expansion thermometers, thanks to the good thermal exchange of the sensor with the fluid. With solid bodies, a good thermal exchange is difficult to be obtainedand an additional measuring error should be considered. When the target is moving or is electrically hazardous, a contact temperature measurement can’t be made. Non-contact IR temperature measurement could be the only solution to the above application problems. Typical application of Applications IRtec portable thermometers is to control temperature where an increase of its value means a possible machine wearing, aging, faulting, etc. |
| Specifications: |
| Models | P800 | P1000 | P 1300 | P1600 | P 2000 |
| Temp. range | -30 to 930°C | -30 to 1000°C | 300 to 1300°C | 600 to 1600°C | 600 to 2000°C |
| Spectral response | 8- 14 μm | 8 -14 μm | 1.6 μm | 0.9 μm | 0.9 μm |
| Target spot size @ distance. Nominal target @ 95% of energy | 10mm@600mm | 10mm@1m | 6mm@1m | 5mm@1m | 5mm@1m |
| D:S target sighting ratio | 60:1 | 100:1 | 167:1 | 200:1 | 200:1 |
| Accuracy IR | ±(1% of rdg+1°C | ±(1% of rdg+1°C | ±(.5% of rdg+1°C | ±(.5% of rdg+1°C | ±(.5% of rdg+1°C |
| Repeatabil-ity IR | ±0.5% of rdg | ±0.5% of rdg | ±0.25% of rdg | ±0.25% of rdg | ±0.25% of rdg |
| Temp stability IR | ±0.01% f.s./°C (for the band exceeding +18°C to +28°C) |
| Measurement sampling time | <300 ms |
| Emissivity | Adjustable from 0.10 to 1.00 |
| Thermocouple measuring ranges | TYPE ‘K’ | TYPE ‘S’ |
| from -100°C to +1370°C - 0.1°C resolution | from 0°C to +1760°C - 0.1°C resolution |
| Thermocouple accuracy | TYPE ‘K’ | TYPE ‘S’ |
| ±(0.05% of reading + 0.4°C) | (0.05% of reading + 2.5°C) |
| Display | High contrast custom LCD with backlight device |
| Display resolution | 1°C / °F / K (0.1°C / 0.1°F in AVG mode up to 200°C) |
| Laser | twin crossed or parallel (suggested for target distance over 5m) |
| Laser indicator | asterisk on display |
| Analog output | 1 mV/ °C/ °F/ K |
| Digital interface` | full bi-directional (RS232 standard isolated available as option |
| Calculated functions | average, max, min, diff. |
| Data memory | 500 input data structured by Tag (max. 20 Tag) |
| Power supply | alkaline or rechargeable (optional) type AA battery |
| Battery life | 16 h (backlight off) |
| Battery low level of charge | symbol on the LCD display |
| Line operation | 100, 115, 230V 10% 50/60 Hz using the external charger |
| Charger transformer insulation | 2500 VDC |
| Battery recharging time | 8 h at 90% (instrument switched off) |
| Operating temperature range | from -10°C to +60°C |
| Case | Injection moulded ABS+ polycarbonate |
| Dimensions | 200x180x80mm |
| Weights | Net 0.8 kg Gross 1.5 kg |